Sign In | Join Free | My disqueenfrance.com
China Newscen Biopharm Co., Limited logo
Newscen Biopharm Co., Limited
Professional Manufacturer of Rapid Test Devices
Active Member

5 Years

Home > HIV Rapid Test Kit >

25ml Plasma HIV test Cassette

Newscen Biopharm Co., Limited
Contact Now

25ml Plasma HIV test Cassette

Brand Name : Newscen

Certification : ISO9001, CE, TUV, SFDA

Place of Origin : China

MOQ : 10 Boxes or 400 Kits (40 Kits/Box)

Price : USD0.48/Cassette

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 100,000 Kits Per Day

Delivery Time : 8 days

Packaging Details : 40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm

Specimen : Serum, Plasma, Whole Blood

Methodology : Colloidal Gold

Shelf Life : 2 Years

Format : Cassette

OEM / ODM : Available

Result Time : Read in 20 Minutes

Contact Now

HIV(1+2) Antibody Rapid Test Kit

For qualitative detection of HIV(1+2) antibodies in serum/plasma and whole blood

Main Features

Sensitivity: 100%

Specificity: Higher than 99%

Simple: No Instrument Required

Ambient Storage

Reliable: able to differentiate HIV Type I and Type II

Certified by Authoritative Certification

Unique 3-line Patented Design

Winner of "the 2008 National HIV Antigen Diagnostic Kit for Clinical Performance Assessment"

25ml Plasma HIV test Cassette

Principle

1. HIV-1(gp41 and gp120) and HlV-2(gp36) specific recombinant antigens are separately precoated on to the membrane inzone1and2as the capture reagent on the test zone.

2. During the test, specimen is allowed to react with the colloidal gold particles, which have been conjugated with HIV-1andHIV-2 specific recombinant antigens.

3. Antibodies to HIV-1 and/or HIV-2, if present, will specifically bind to colloidal gold-antigen complex.

4. When the colloidal gold-antigen-antibody complexes move to the test zone, they will specifically bind to the precoated antigens. At the same time, a red colored line will develop in zone 1 and/or 2 on the membrane. Absence of these red colored lines in the test zone ( 1 and 2) suggests a negative result.

5. To serve as a procedural control, red colored line in the control zone will always appear regardless of the presence of antibodies to HIV-1/HIV-2.

25ml Plasma HIV test Cassette

Reagents and Materials Provided

Each kit contains:

40 test cassettes(individually pouched)

Each pouch contains one cassette with one desiccant bag

One bottle of diluent buffer(5ml)

40 disposable plastic droppers

Instruction for use

Materials Required But Not Provided

Timer or stopwatch

Blood collection devices, for the testing of venous whole blood, serum or plasma

Biohazard disposal container

Disposable gloves

For finger stick samples, the following materials are required:

Alcohol pad

Sterile lancet

Sterile gauze or cotton

25ml Plasma HIV test Cassette

Assay Procedure

Place the test cassette on flat surface. Before unseal the pouch, allow the test cassette to reach room temperature(4-30°C) .Use it immediately once unsealed.

Open the pouch and add1drop(30-40uL) of specimen into the sample well(s) .

When the specimen is completely absorbed, slowly add1drop(45-55pL) of diluent buffer vertically into the sample well(s) .

Avoid dropping specimen or diluent buffer in the observation window.

Do not allow the diluent buffer bottle touch the sample well when dropping the diluent buffer so as to prevent the cross contamination with the specimen.

Observe the result between 15-30 minutes after the diluent buffer added.

Interpretation of Results

25ml Plasma HIV test Cassette

Note:‘C'-Control line; ‘1'-HIV-1 Test line; ‘2'-HIV-2 Test line

Negative: No redlines appear within 30 minutes in the test zone( 1 and 2), only a redline in the control zone(C) , which indicates that no antibodies to HIV 1+ 2 have been detected with this test. However, this does not exclude the possibility from infection with HIV.

Positive: One redline in the control zone(C) and one or two red visible lines of any intensity in the test zone( 1 and 2) .This indicates the specimen contains HIV-1 and/or HIV-2 antibodies.

Invalid: No redlines appear in the control zone(C), regardless of whether there is a redline in the test zone( 1 and 2) , indicating that the test is invalid. Discard the test cassette and perform with new cassette.

Built-In Control

Newscen HIV(1+2) Antibody Rapid Test has a built-in procedural control that demonstrates assay validity. A redline appeared on the control zone(C) indicates that the test runs correctly.

Warning

For Invitro Diagnostic Use ONLY

Read the package insert completely before use. It is very important that the correct procedure is followed. Fail to add the patient sample may lead to a false negative result (i.e.a missed positive) .

Storage

Newscen HIV(1+2) Antibody Rapid Test should be stored at room temperature(4-30℃, do not freeze)

for 24 months from the date of manufacture. Keep the test cassette in sealed pouch until use. Once you have taken the test cassette out of the pouch, perform the test as early as possible(within 1hour) to avoid test cassette from becoming moist. Do not use the test beyond the indicated expiration date.

The diluent buffer should be stored at room temperature(4-30℃, do not freeze)

25ml Plasma HIV test Cassette

25ml Plasma HIV test Cassette

25ml Plasma HIV test Cassette


Product Tags:

25ml Plasma HIV Rapid Test Kit

      

100% HIV Rapid Test Kit

      

25ml Plasma HIV test Cassette

      
China 25ml Plasma HIV test Cassette wholesale

25ml Plasma HIV test Cassette Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Newscen Biopharm Co., Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0